Please use this identifier to cite or link to this item: http://thuvienso.dut.udn.vn/handle/DUT/6001
DC FieldValueLanguage
dc.contributor.advisorTS. Nguyễn, Lê Hòaen_US
dc.contributor.advisorTS. Arjon Turnipen_US
dc.contributor.authorNguyễn, Thị Nhật Ngânen_US
dc.contributor.authorNguyễn, Hữu Hoàng Hảien_US
dc.contributor.authorHồ, Quang Đại Việten_US
dc.date.accessioned2025-04-22T04:24:54Z-
dc.date.available2025-04-22T04:24:54Z-
dc.date.issued2023-
dc.identifier.urihttp://thuvienso.dut.udn.vn/handle/DUT/6001-
dc.description61 tr.en_US
dc.description.abstractPhotoplethysmography (PPG) is a noninvasive method for detecting vital indicators such as blood pressure, heart rate, and the saturation of peripheral oxygen (SpO2) (BP). To make it simple for doctors to keep an eye on patients' health, a PPG processing system was proposed to estimate blood pressure (BP). This system is applied to Medical Robot. Motion artifacts were removed by using Min Max Scaler Normalization and 20 Hz cut-off frequency Low Pass filter. As a result, data accuracy and quality have increased noticeably. We suggested an AI technical system named the Adaptive Neuro-Fuzzy Inference System (ANFIS) based on the ANN algorithm to assist in estimating critical indicators like SBP and DBP. Python and MATLAB are the two primary languages and tools for processing the incoming data to generate the most accurate outputFifteen records (15 patients) were sensed and used for training and testing purposes. The Root Mean Squared Error (RMSE) of the testing data were 0.23 and 0.11 respectively for Diastolic Blood Pressure (DBP) and Systolic Blood Pressure(SBP). The conventional and specialized system for BP estimation was statistically proven. Building an IOT system that records vital data into a database and then displays it on mobile applications, PC screens, etc. is a solution to letting slimmers monitor patients more quickly, more efficiently, and more easilyen_US
dc.language.isoenen_US
dc.publisherTrường Đại học Bách khoa - Đại học Đà Nẵngen_US
dc.subjectPPG signal processingen_US
dc.subjectApplication for medical roboten_US
dc.titlePPG signal processing for estimation of blood pressure using anfis method – Application for medical roboten_US
dc.typeĐồ ánen_US
dc.identifier.id2.DA.FA.23.107-
item.grantfulltextrestricted-
item.languageiso639-1en-
item.fulltextCó toàn văn-
item.openairetypeĐồ án-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:DA.Điện tử - Viễn thông
Files in This Item:
File Description SizeFormat Existing users please Login
2.DA.FA.23.107.Nguyen Thi Nhat Ngan.pdfThuyết minh3.4 MBAdobe PDF
Show simple item record

CORE Recommender

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.